The NXE4002 is a 2-channel 400W network power amp. nX Power Amplifiers feature lightweight, energy-efficient Class-D switching amplifier technology combined with a switch mode power supply.
Available in three product families, nX is designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.
nXe Series is the networkable version of the nX amplifier with the addition of Ethernet control, serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability.
- 2-channel high-output, lightweight amplifiers withprogrammable output on each channel (High-Z or Low-Z, selected via rear panelDIP switches)
- Power-saving, Energy Management System‡ (Ashly EMS™)automatic <1W sleep-mode (defeatable)
- Front panel power switch and level controls (can bedisabled for security)
- Rear panel DIP switches per channel for selection ofhigh pass filter, limiter, input gain, and High-Z or Low-Z speaker outputconfiguration
- Remote DC level control on each input channel
- Switch mode power supply automatically detects 120Vor 240V AC operation
- Extensive protection circuitry, continuously variablecooling fans
- Multiple independent internal power supplies provideincreased channel separation and reliability
- Ethernet port for use with control and monitoring ofamplifier functions, with front panel COM activity LED
- Serial data port for use with Ashly remote controldevices, or optional RS-232 converter for third party controllers (INA-1)
- Use Protea™ Software to remotely disable all frontpanel controls, including the on/off switch, for a tamper-proof installation
- Real-Time Clock with Event Scheduler
- Instant Standby Mode, 30% reduction in powerconsumption with on/off triggered by contact closure, software control, orevent scheduler
- Programmable power-on delay
- Preset recall via contact closure, software control,remote control, or event scheduler
- Aux preamp outputs, and fault condition logic outputs
- Optional Cobranet® or Dante® network audio and AES3digital audio input with pass-through
- Neutrik® Combo XLR - 1/4" TRS jack plus Euroblockinput connectors
- Neutrik® speakON® twist locking loudspeakerconnectors for security, safety, and reliability
- Neutrik® powerCON® detachable AC mains connector