SmartSequencing With Advanced Power Protection
The CN-2400S, which was created for commercial audiovisual installers, combines powerful control capabilities with SmartSequencingTM Technology, robust AC protection, AC noise filtration, and optional connectivity with the BlueBOLT® Remote Power and Energy Management Platform (BB-RS232 adaptor required, sold separately).
The new CN-2400S is among the first devices to include Furman's SmartSequencingTM technology, which enables extensive and complex A/V systems to be securely switched on and off with an easy press of a button or twist of a key, even by nontechnical staff. A primary unit may control and sequence numerous secondary units using SmartSequencing's bidirectional communications between installed devices, guaranteeing that multizone electronic systems are turned on and off reliably and safely from a single control point throughout an entire installation. Featuring backwards compatibility with Furman's vintage sequencers, units may be connected through current loop at distances of more than 1,000 feet.
The CN-2400S also provides extensive control choices, RS-232 connections, and command sets for integrating with control systems. The unit may be fully IP-addressable with the help of an optional RS-232-to-Ethernet converter (available separately), allowing it to be managed remotely from a smartphone, tablet, PC, or other Web-enabled device via Telnet, a direct HTTP connection, or Panamax/BlueBOLT® Furman's platform.
- AC Voltage Input Range: 90-139VAC, 50/60Hz
- Maximum AC Current Rating: 20 amps (Thermal breaker)
- AC Cord 3/12AWG, 10 feet, black, fixed, NEMA 5-20P plug
- Rear Panel Outlets: 2 Unswitched NEMA 5 20R’s (1 duplex), 6 Sequenced NEMA 5-20R’s (3 duplexes each controlled by separate relay)
- Front Panel: One NEMA 5-15R Convenience Outlet, Unswitched
- AC Surge Protection: SMP
- Spike Protection Mode: Line to neutral, zero ground leakage
- Spike Clamping Voltage: 188VAC peak @ 6,000 volts/3,000 amps
- Response Time: 1 nanosecond
- Maximum Surge Current: 6,500 Amps
- AC Undervoltage Protection: EVS, 77VAC+/-3VAC
- AC Overvoltage Protection: EVS, 145VAC+/-5VAC
- AC Overvoltage Reset Modes: Manual and Auto-reset (configurable)
- AC Filtering: LiFT
- Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz
- Operating Temperature Range: 5C (40F) to 40C (105F) degrees
- Humidity Range: <90% rH (Relative Humidity)
- Keyswitch: Front panel, 3-position keyswitch (On, Off, Remote)
- Keys Included, 1 pair
- Pushbutton Switch: Front panel, hidden by security cover
- Circuit Breaker: Front panel, pushbutton, 20A Thermal Breaker Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage
- DIP Switches: Front panel. Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
- Potentiometer: Front panel, hidden by security cover, fine tune delay adjust
- Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
- SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop – 1000’ nominal)
- Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring) Force Off/Delay 3 Terminal Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring)
- RS-232 Compatible: Yes, DB-9 Connector
- IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adaptor (sold separately) for IP control via Telnet, HTTP, BlueBOLT®