Featuring Advanced Series Mode surge elimination technology, the SurgeX Rack Mount product line safeguards sensitive equipment that relies on audio and video performance. Unlike common protection solutions, our patented technology is non-sacrificial and eliminates surge energy up to 6,000 volts without producing harmful side effects such as ground contamination or common-mode disturbances that can degrade the performance of AV systems.
With SurgeX rack mount solutions your connected equipment will be protected from destructive spikes, surges, and inductive transients that can cause disruptions and catastrophic damage.
The SurgeX Rack Mount product line provides professional-grade surge elimination and power conditioning for audio, video, and security rack mount equipment. Our top-of-the-line protection is the ultimate solution to safeguard audio video systems that rely on mission critical equipment for optimal performance.
- Advances Series Mode ® surge elimination technology
- Catastrophic over/under Voltage Shutdown Protection
- ICE Inrush Current Elimination
- EMI/RFI filter
- Thermal circuit breaker overload protection
- Improves audio and video performance
- Non-sacrificial components
- A-1-1 Certified
- Load Rating: 15 @ 120 volts
- Power Requirement (no load): 15 watts
- Surge Let-Through Voltage (6000-volt surge): 0 Volts
- UL 1449 Adjunct Classification Test Results: 1000 surges, 6000 volts, 3000 amps,
B3 pulse - Measured suppressed voltage: 170 volts, no failures
- Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
- EMI/RFI Filter, Normal Mode (50-ohm load)
- 40 dB @ 100 kHz; 50 dB @ 300 kHz;
- 50 dB @ 3 MHz; 50 dB @ 30 MHz
- EMI/RFI Filter, Common Mode (50-ohm load)
- 18 dB @ 300 kHz; 30 dB @ 1 MHz;
- 50 dB @ 5 MHz; 50 dB @ 20 MH
- Maximum Applied Surge Voltage: 6000 volts*
- Maximum Applied Surge Current: Unlimited, due to current limiting*
- Maximum Applied Surge Energy: Unlimited, due to current limiting*
- Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000
- Undervoltage Shutdown: 90 volts (resume at 100 v)
- Overvoltage Shutdown: 145 volts (resume at 135 v)
- Maximum Load Inrush Current During Power-up: 1000 Joules
- Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
- Contact Closure: 1.5 mA
- 5 V DC Applied Voltage: 0.1 mA;
- 12 V DC Applied Voltage: 1.5 mA
- 24 V DC Applied Voltage: 5.0 mA
- Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
- LED Output: 12 volts DC, maximum 20 mA (resistor required)
- Dimensions: 1.75″ H x 19″ W x 10.5″ D (4.5 x 48.3 x 26.7 cm)
- Weight: 11 lbs (5 kg)
- Temperature Range: 5º to 35º C
- Humidity Range: 5% to 95% R.H., non-condensing
- Agency Listings: ETL and cETL certified to (UL 1449; CSA C22.2 No.8-M1986, R2000)
* 1.2 x 50 μs pulse, industry standard combination wave surge, as per IEEE C62.41
** Specifications subject to change without notice.
This product, including its components and/or processes carried out thereby, are covered by one or more of the following:
U.S. Pat. No. 4,870,534. 4,870,528. 6,728,089. 6,744,613. 7,068,487. Can. Pat. No. 1,333,191. 1,332,439. Other Patents Pending.